Procedure for Shutting down the GC
For more than one week Set all heated zones to ambient temperature and turn off the detector support gas flows. Leave the carrier

For more than one week Set all heated zones to ambient temperature and turn off the detector support gas flows. Leave the carrier

An on-off cycle burns the filament and will eat approximately 15 hours of a lamps lifetime. The guaranteed number of hours should be

Turn off the flow of sample solution from the LC (or other sample introduction device). In the Tune window, click the System Off

In the Tune window, click the System Off button () to put the instrument in Off condition. All high voltages are shut off, as are the

Learn how to safely shut down your GC/GCMS instruments with this 2020 guide. Includes steps for Trace, Focus, ISQ, and TSQ series.

Access the resources below to ensure proper shutdown and start-up of your analytical instruments. For additional information or

How to shut down or vent a Xevo or Synapt for a planned shutdown. Remove all fluidics calibration and lockmass standards and

Turn off the GC safely. This article outlines both short term (one week or less) and long term (more than one week)

How to Shut Down the Mass Spectrophotometer - Free download as Word Doc (.doc / .docx), PDF File (.pdf), Text File (.txt) or read

To safely shut down a mass spectrophotometer during a power outage: 1) Turn off the Orbitrap electronics and vacuum pumps using

Spray chamber voltages, the drying gas heater, the nebulization gas flow, the detector, and other specific lens voltages are all turned

Place the main power circuit breaker switch, located on the power panel on the left side panel of the mass

To turn the spectrophotometer off, flip the power switch on the back of the machine. DO NOT move the

It should then turn red. Turn off all gasses. Take a screen capture of the vacuum view to record the vacuum before venting. To do

Before you remove the source from the spectrometer, turn off the instrument power, unplug the power cord, disconnect any purge

You can then turn the MS and GC off and turn the helium off too. When starting back up, turn on the helium, hold the

Power-off the Xevo or SQD using the power button on the front, upper-left corner of the instrument. (You may also choose to unplug

Wait until data acquisition, if any, is complete. Turn off the flow of solvent from the LC (or other sample introduction

Push the switch to “0” to turn it off. Switch / Testing button: Long press for 3 seconds to turn ON/OFF power, short press for

Learn how to troubleshoot common spectrometer issues and get better results. Discover expert-backed support from

Turn the power switch to the ON position. Wait for the lamp indicator LED to remain green. If connecting via USB:

To turn the spectrophotometer off, flip the power switch on the back of the machine. DO NOT move the

Resolution If you need to turn off the MS detector in an emergency follow these steps: Place the main power switch

Introduction The Ocean Optic QE Pro Spectrometer is a scientific-grade spectrometer with broadband sensitivity, from UV to NIR,

Unless the system will be idle for some time or will be moved, we recommend that the spectrometer not be turned off. The computer

OBJECTIVE: In case of a power outage, stop the vacuum of Xevo TQ-S micro and power off PROCEDURE: 1. Open the Inlet

A spectrophotometer is a device used to measure light at a specific wavelength. It consists of two parts: a

2. Turn off the Electronics Service Switch. 3. After one minute, turn off the Mass Spectrometer Main Power Switch to the Off (O)

To troubleshoot your instrument, switch the instrument off. Then push the power button of the spectrophotometer to switch it on

Unplug the mass spectrometer''s power cord from the electrical outlet. CAUTION Do not disconnect the power supply cord from the

This user guide provides instructions on how to use the X-Rite Ci6X Ci60, Ci62, Ci64, and Ci64UV spectrophotometers for color
Our team can help review your product selection.